Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 410
Filter
1.
Int J Cardiol ; : 132118, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38697397

ABSTRACT

BACKGROUND: To assess long-term effectiveness and safety of edoxaban in Europe. METHODS AND RESULTS: ETNA-AF-Europe, a prospective, multinational, multi-centre, post-authorisation, observational study was conducted in agreement with the European Medicines Agency. The primary and secondary objectives assessed real-world safety (including bleeding and deaths) and effectiveness (including stroke, systemic embolic events and clinical edoxaban use), respectively. Median (interquartile range) age of the 13,164 patients was 75.0 (68.0-80.0) years; CHA2DS2-VASc and HAS-BLED scores were 3.0 (2.0-4.0) and 2.0 (1.0-2.0), respectively. Follow-up duration was 3.98 (3.21-4.05) years. Patients on edoxaban 30 mg (n = 3042) at baseline were older (80.0 vs 73.0 years), more likely assessed as frail by investigators (27.0% vs 6.6%) and had more comorbidities than those on edoxaban 60 mg (n = 9617; missing dosing information for n = 505). Annualised event rates of all-cause and cardiovascular death in the overall population, edoxaban 60 mg and edoxaban 30 mg groups were 4.1%, 2.8% and 8.4%, and 1.0%, 0.7% and 2.0%, respectively. Annualised rates of stroke were relatively constant throughout the follow-up, transient ischaemic attack and systemic embolism were < 1% in the overall population. Rates of any major and major gastrointestinal bleeding were low, with slightly higher rates for edoxaban 30 vs 60 mg group. Intracranial haemorrhage was uncommon (0.2%). CONCLUSIONS: In European patients with AF, long-term therapy with edoxaban is associated with low and relatively constant annualised rates of stroke and major bleeding. Differences in outcomes between the two approved doses are attributable to differences in clinical characteristics.

2.
J Am Heart Assoc ; : e033148, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726893

ABSTRACT

BACKGROUND: Brugada syndrome (BrS) has been associated with sudden cardiac death in otherwise healthy subjects, and drug-induced BrS accounts for 55% to 70% of all patients with BrS. This study aims to develop a deep convolutional neural network and evaluate its performance in recognizing and predicting BrS diagnosis. METHODS AND RESULTS: Consecutive patients who underwent ajmaline testing for BrS following a standardized protocol were included. ECG tracings from baseline and during ajmaline were transformed using wavelet analysis and a deep convolutional neural network was separately trained to (1) recognize and (2) predict BrS type I pattern. The resultant networks are referred to as BrS-Net. A total of 1188 patients were included, of which 361 (30.3%) patients developed BrS type I pattern during ajmaline infusion. When trained and evaluated on ECG tracings during ajmaline, BrS-Net recognized a BrS type I pattern with an AUC-ROC of 0.945 (0.921-0.969) and an AUC-PR of 0.892 (0.815-0.939). When trained and evaluated on ECG tracings at baseline, BrS-Net predicted a BrS type I pattern during ajmaline with an AUC-ROC of 0.805 (0.845-0.736) and an AUC-PR of 0.605 (0.460-0.664). CONCLUSIONS: BrS-Net, a deep convolutional neural network, can identify BrS type I pattern with high performance. BrS-Net can predict from baseline ECG the development of a BrS type I pattern after ajmaline with good performance in an unselected population.

3.
J Clin Med ; 13(5)2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38592135

ABSTRACT

Sudden cardiac death (SCD) accounts for a substantial proportion of mortality in heart failure with reduced ejection fraction (HFrEF), frequently triggered by ventricular arrhythmias (VA). This review aims to analyze the pathophysiological mechanisms underlying VA and SCD in HFrEF and evaluate the effectiveness of guideline-directed medical therapy (GDMT) in reducing SCD. Beta-blockers, angiotensin receptor-neprilysin inhibitors, and mineralocorticoid receptor antagonists have shown significant efficacy in reducing SCD risk. While angiotensin-converting enzyme inhibitors and angiotensin receptor blockers exert beneficial impacts on the renin-angiotensin-aldosterone system, their direct role in SCD prevention remains less clear. Emerging treatments like sodium-glucose cotransporter 2 inhibitors show promise but necessitate further research for conclusive evidence. The favorable outcomes of those molecules on VA are notably attributable to sympathetic nervous system modulation, structural remodeling attenuation, and ion channel stabilization. A multidimensional pharmacological approach targeting those pathophysiological mechanisms offers a complete and synergy approach to reducing SCD risk, thereby highlighting the importance of optimizing GDMT for HFrEF. The current landscape of HFrEF pharmacotherapy is evolving, with ongoing research needed to clarify the full extent of the anti-arrhythmic benefits offered by both existing and new treatments.

4.
Biomedicines ; 12(4)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38672223

ABSTRACT

To date, studies assessing the safety profile of 3D printing materials for application in cardiac ablation are sparse. Our aim is to evaluate the safety and feasibility of two biocompatible 3D printing materials, investigating their potential use for intra-procedural guides to navigate surgical cardiac arrhythmia ablation. Herein, we 3D printed various prototypes in varying thicknesses (0.8 mm-3 mm) using a resin (MED625FLX) and a thermoplastic polyurethane elastomer (TPU95A). Geometrical testing was performed to assess the material properties pre- and post-sterilization. Furthermore, we investigated the thermal propagation behavior beneath the 3D printing materials during cryo-energy and radiofrequency ablation using an in vitro wet-lab setup. Moreover, electron microscopy and Raman spectroscopy were performed on biological tissue that had been exposed to the 3D printing materials to assess microparticle release. Post-sterilization assessments revealed that MED625FLX at thicknesses of 1 mm, 2.5 mm, and 3 mm, along with TPU95A at 1 mm and 2.5 mm, maintained geometrical integrity. Thermal analysis revealed that material type, energy source, and their factorial combination with distance from the energy source significantly influenced the temperatures beneath the 3D-printed material. Electron microscopy revealed traces of nitrogen and sulfur underneath the MED625FLX prints (1 mm, 2.5 mm) after cryo-ablation exposure. The other samples were uncontaminated. While Raman spectroscopy did not detect material release, further research is warranted to better understand these findings for application in clinical settings.

6.
Heart Rhythm ; 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38614189

ABSTRACT

BACKGROUND: A rare gene variant in SCN5A can be found in approximately 20%-25% of patients with Brugada syndrome (BrS). OBJECTIVE: The aim of this systematic review and meta-analysis was to evaluate the differences in clinical characteristics of BrS patients with and without SCN5A rare variants and the prognostic role of SCN5A for ventricular arrhythmias in BrS. METHODS: PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were systematically searched from inception to January 2024 to identify all relevant studies. Studies were analyzed if they included patients diagnosed with BrS in whom genetic testing for SCN5A variants was performed and arrhythmic outcomes were reported. RESULTS: A total of 17 studies with 3568 BrS patients, of whom 3030 underwent genetic testing for SCN5A variants, fulfilled the eligibility criteria and were included. Compared with SCN5A- patients, SCN5A+ BrS patients more frequently had spontaneous type 1 electrocardiogram, history of syncope, and documented arrhythmias. Furthermore, higher PQ and QRS intervals in SCN5A+ BrS patients compared with SCN5A- have been found. The pooled analysis demonstrated a significant association between the presence of SCN5A rare variants in BrS patients and the risk of major arrhythmic events, with a pooled odds ratio of 2.14 (95% confidence interval, 1.53-2.99; I2 = 29%). CONCLUSION: SCN5A+ BrS patients showed a worse clinical phenotype compared with SCN5A-. The pooled analysis demonstrated a significant association between SCN5A+ mutation status and the risk of major arrhythmic events in BrS patients.

7.
Heart Rhythm O2 ; 5(2): 137-144, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38545325

ABSTRACT

Background: Pericarditis is the most common complication following hybrid sinus node-sparing ablation for inappropriate sinus tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS). Objective: The study sought to evaluate the association of prophylaxis therapy on the risk of symptomatic pericarditis following hybrid IST/POTS ablation. Methods: All consecutive patients undergoing to hybrid ablation of symptomatic IST/POTS refractory or intolerant to drugs were retrospectively analyzed. Pharmacological prophylaxis therapy was based on acetylsalicylic acid and colchicine started on the day of the ablation and continued for at least 3 months. The primary endpoint was occurrence of symptomatic pericarditis. The secondary endpoint was occurrence of pericarditis-related complications, including the following: duration of pericarditis >3 months, hospitalization for pericarditis, postpericardiectomy pleuro-pericarditis, and pericardiectomy. Results: A total of 220 patients undergone to hybrid IST/POTS ablation were included and 44 (20%) underwent prophylaxis therapy. Pericarditis occurred in 101 (45.9%) patients, with 97 (96%) in the first 5 days. At survival analysis, prophylaxis was associated with higher rate of freedom from pericarditis (81.9% vs 47.2%, log-rank P < .001). Pericarditis-related complications were low, occurring in 7 (3.2%) patients. There was no difference in pericarditis-related complications between the patients who underwent prophylaxis therapy and patients who did not. At Cox multivariate analysis, predictors of pericarditis were IST (vs POTS) (hazard ratio 0.61, 95% confidence interval0.39-0.99, P = .04) and prophylaxis therapy (hazard ratio 0.27, 95% confidence interval 0.13-0.55, P < .001). Conclusion: In a large cohort of patients undergoing hybrid ablation for IST/POTS, a prophylaxis therapy with acetylsalicylic acid and colchicine was associated with a lower rate of symptomatic pericarditis.

8.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38449430

ABSTRACT

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Cardiac Pacing, Artificial/adverse effects , Arrhythmias, Cardiac/therapy , Heart Rate/physiology
10.
J Cardiovasc Electrophysiol ; 35(4): 832-842, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38448797

ABSTRACT

INTRODUCTION: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS: The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS: This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Heart Injuries , Pulmonary Veins , Humans , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Heart Injuries/etiology , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
12.
Circ Arrhythm Electrophysiol ; 17(4): e012374, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38426305

ABSTRACT

BACKGROUND: A pathogenic/likely pathogenic variant can be found in 20% to 25% of patients with Brugada syndrome (BrS) and a pathogenic/likely pathogenic variant in SCN5A is associated with a worse prognosis. The aim of this study is to define the diagnostic yield of a large gene panel with American College of Medical Genetics and Genomics variant classification and to assess prognosis of SCN5A and non-SCN5A variants. METHODS: All patients with BrS, were prospectively enrolled in the Universitair Ziekenhuis Brussel registry between 1992 and 2022. Inclusion criteria for the study were (1) BrS diagnosis; (2) genetic analysis performed with a large gene panel; (3) classification of variants following American College of Medical Genetics and Genomics guidelines. Patients with a pathogenic/likely pathogenic variant in SCN5A were defined as SCN5A+. Patients with a reported variant in a non-SCN5A gene or with no reported variants were defined as patients with SCN5A-. All variants were classified as missense or predicted loss of function. RESULTS: A total of 500 BrS patients were analyzed. A total of 104 patients (20.8%) were SCN5A+ and 396 patients (79.2%) were SCN5A-. A non-SCN5A gene variant was found in 75 patients (15.0%), of whom, 58 patients (77.3%) had a missense variant and 17 patients (22.7%) had a predicted loss of function variant. At a follow-up of 84.0 months, 48 patients (9.6%) experienced a ventricular arrhythmia (VA). Patients without any variant had higher VA-free survival, compared with carriers of a predicted loss of function variant in SCN5A+ or non-SCN5A genes. There was no difference in VA-free survival between patients without any variant and missense variant carriers in SCN5A+ or non-SCN5A genes. At Cox analysis, SCN5A+ or non-SCN5A predicted loss of function variant was an independent predictor of VA. CONCLUSIONS: In a large BrS cohort, the yield for SCN5A+ is 20.8%. A predicted loss of function variant carrier is an independent predictor of VA.


Subject(s)
Brugada Syndrome , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/genetics , Genetic Testing , Arrhythmias, Cardiac/genetics , Mutation, Missense , NAV1.5 Voltage-Gated Sodium Channel/genetics , Mutation
13.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38445836

ABSTRACT

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Subject(s)
Brugada Syndrome , Defibrillators, Implantable , Pacemaker, Artificial , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Electrocardiography, Ambulatory/methods , Adult
14.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38310489

ABSTRACT

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Subject(s)
Acute Kidney Injury , Atrial Fibrillation , Catheter Ablation , Hemoglobinuria , Humans , Atrial Fibrillation/surgery , Male , Female , Catheter Ablation/adverse effects , Catheter Ablation/methods , Middle Aged , Acute Kidney Injury/prevention & control , Acute Kidney Injury/etiology , Aged , Hemoglobinuria/etiology , Hemoglobinuria/prevention & control , Creatinine/blood , Retrospective Studies , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Fluid Therapy/methods
16.
Article in English | MEDLINE | ID: mdl-38261100

ABSTRACT

INTRODUCTION: The aim of this study was to report the long-term follow-up results of cryoballoon (CB) ablation in patients with atrial fibrillation. METHODS: All consecutive patients who underwent second-generation CB ablation from February 2015 to December 2017 were included in our study. In all procedures, we used a 28-mm CB placed via a single transseptal puncture guided by intracardiac ultrasound. A 20-mm octapolar intraluminal circular catheter was used for intracardiac recordings. A single 180-s freeze strategy was employed. Repeated procedures were performed with a 3D mapping system and radiofrequency catheters. RESULTS: A total of 126 patients (69.8% male, mean age 57 ± 11 years), of which 77.0% had paroxysmal atrial fibrillation (PAF), were included in the study. After a 5-year period, 52.4% of patients were in sinus rhythm without AF recurrence, off antiarrhythmic drugs. A total of 61.9% of patients were free of AF recurrence when redo PVI procedures were performed. When accounting for redo pulmonary vein isolation and antiarrhythmic drugs, a total of 73.8% of the patients were without AF recurrence in long-term follow-up. The patients who underwent redo pulmonary vein isolation procedures had statistically significant lower rates of AF recurrence (p = 0.006). In patients with PAF, long-term success rates improved from 62.9 to 79.4% for patients who underwent the redo procedure (p = 0.020). In patients with persistent atrial fibrillation (PersAF), success rates went up from 41.4 to 55.1% for patients with single or repeated PVI procedure (p = 0.071). In the whole cohort, a total of 3 (2.4%) procedure-related major complications occurred which included persistent PNP, arterial pseudoaneurysm, and arteriovenous fistula. CONCLUSION: Our data suggest a favorable long-term safety and efficacy profile of second-generation CB ablation. In the mixed paroxysmal and persistent population, up to 73.8% of patients remained free of AF recurrence in the 5-year follow-up, when accounting for redo procedures and AADs. Only 2.4% of patients experienced major complications of the ablation procedure, none with permanent sequelae.

17.
Heart Rhythm ; 2024 Jan 28.
Article in English | MEDLINE | ID: mdl-38290688

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE: The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS: Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS: Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION: PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.

18.
Heart Rhythm ; 2024 Jan 20.
Article in English | MEDLINE | ID: mdl-38246567

ABSTRACT

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.

19.
J Interv Card Electrophysiol ; 67(2): 273-283, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37103590

ABSTRACT

BACKGROUND: Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA). METHODS: We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience. RESULTS: Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise. CONCLUSIONS: RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Cryosurgery/methods , Feasibility Studies , Treatment Outcome , Catheter Ablation/methods , Recurrence , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Catheters
20.
JACC Clin Electrophysiol ; 10(3): 477-486, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38069973

ABSTRACT

BACKGROUND: Studies have reported development of pulmonary hypertension (PH) secondary to reduced LA compliance following AF ablation. OBJECTIVES: This study aimed to compare the risk of worsening of baseline PH between non-paroxysmal AF patients undergoing pulsed-field ablation (PFA) and standard radiofrequency ablation (RFA). METHODS: This multicenter study included 28 nonparoxysmal AF patients with PH undergoing a PFA-based ablation procedure after >1 failed RFA. A cohort of 28 AF patients with PH, scheduled for repeat RFA, 1:1 propensity-score matched using a multivariable logistic model, were used as the comparator group. Right heart catheterization and echocardiography were performed before and after the procedure to assess the pulmonary artery pressure (PAP). PH was defined as resting mean PAP of >20 mm Hg. RESULTS: The baseline characteristics of the PFA and propensity-matched RFA groups were comparable. The mean PAP assessments at baseline, follow-up, and change from baseline were analyzed. The groups had comparable baseline mean pulmonary artery pressures (mPAP) (P = 0.177). After adjustment for baseline mPAP in an analysis of covariance model, the least-squares means change at 3 months after ablation was -1.71 ± 1.03 mm Hg and 19.67 ± 1.03 mm Hg in PFA and RFA, respectively (P <0.001). CONCLUSIONS: In this propensity-matched population, no worsening of mPAP was detected following pulsed-field ablation in patients with pre-existing PH undergoing a repeat procedure for recurrence.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Hypertension, Pulmonary , Radiofrequency Ablation , Humans , Atrial Fibrillation/surgery , Hypertension, Pulmonary/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Radiofrequency Ablation/adverse effects , Cardiac Catheterization
SELECTION OF CITATIONS
SEARCH DETAIL
...